Duct Design for Great Results w/ Ed Janowiak (ACCA) HVAC School Kho Tổng Hợp 166,958 5 năm trước Add Nghe mp3 Facebook Tweet XEM MÔ TẢ Ed Janowiak of ACCA gives a presentation about fan and duct design, system testing, and Manual D at the second annual HVACR Training Symposium. Learn more about the 2022 HVACR Training Symposium at https://hvacrschool.com/symposium/. Ed has over 35 years of HVACR experience, both in the field and through teaching. He has lived and done business in New Jersey, which has a variable climate, and he has experienced a wide range of temperatures. When designing ductwork, we obviously want our static pressure to be close to our calculations. However, lower static pressure is usually more desirable than higher static pressure. When static pressures exceed our expectations, we have to start removing elements of our design. The real key to good duct design is managing the occupant’s expectations. Understand what the client wants, but you must be up-front with what they can and cannot expect from their HVAC system. Manual D requires that you pick a fan and design the ductwork around the fan. Ducts must accommodate fan pressure. (Manual Q is the opposite; you choose the fan based on the duct resistance.) Manual D’s goal is to calculate the critical path, which is the longest circulation path in the system. It’s also a good idea to comply with local codes, but it is not responsible for a design’s predictability. To design a duct system, we also need to know how much BTUH (BTUs per hour) and CFM (cubic feet per minute) need to be delivered. We can get these figures by finding the BTU gain and loss (Manual J), and we can use Manual S to calculate our target airflow. Take the SHR (sensible heat ratio) into account, and you use all of that data to find your capacity. We should refer to the friction rate worksheet to develop a good duct design. You initially take your external static pressure and CFM readings. Then, you discover and note the component pressure drops. You also take available static pressure and total effective length into account. In the end, you will figure out your friction rate. The purpose of that worksheet is to determine the friction rate based on the duct system’s critical path. We use manometers to take static pressure measurements. Static pressure is NOT velocity; it is the measure of pressure against the walls of the duct. You can use static pressure as an airflow indicator. Several components can contribute to pressure losses in the critical path, including heat exchangers, UV lights, grilles, and dampers. However, the filter is the most notorious source of pressure drops. When sizing a filter, you need to know CFM, velocity, and area. The system must have enough pressure to overcome those drops in the system. Once you have calculated your external static pressure and losses, you can subtract those losses from your external static pressure to yield your available static pressure. You determine your total effective length by adding the supply and return-side total effective lengths together (including trunks, runouts, and group fittings of each one’s critical path). Then, to get the friction rate, you multiply your available static pressure by 100 and divide that product by the total effective length. (You should also be able to find that value on a chart on the friction rate worksheet.) Humans feel comfortable when they don’t notice their surroundings. So, excessive fan noise can be an unexpected source of discomfort for occupants. Watch your air velocity to avoid creating that humming sound with the fan. Don’t start off at high speed! Manual D gives us maximum air velocity guidelines to avoid comfort issues. Manual T also covers terminal velocity and grille selection, which heavily contributes to comfort. (A grille should be located in a sensible location and should have the proper throw. Grille size will determine the distribution box size.) You must determine your heating and cooling factors to begin working on your duct design worksheet. The heating factor is the blower CFM divided by your Manual J heat loss; your cooling factor is the blower CFM divided by your Manual J heat gain. When you use effective length charts, you must keep in mind that those effective lengths will only contribute to duct behavior predictably under a certain set of conditions. If you’re running at a slower fan velocity the friction rate will change, and you will need to do some more calculations. As friction goes up, effective length goes down. Our external static pressures may end up higher than we anticipated due to excess length (with flex duct). Ed also discusses: Alternative ways to measure static pressure Height-to-width ratio of ducts Design software pitfalls Return drop sizing Sizing for flex duct systems Round registers Grille air velocity and sizing Filter sizing Standard test airflow rates for MERV ratings Read all the tech tips, take the quizzes, and find our handy calculators at https://www.hvacrschool.com/. Video liên quan 45:02 Gemini im Auto, Amazon ersetzt Jobs & OpenAI Atlas – Wie weit geht Automatisierung? Ki-Wegweiser 145 view 11 tháng trước Add 15:32 Verzwickte Situation: Rechtsbrecher als Nachbarn | Nachbarschaftsstreit | ATV ATV Blaulicht 14,543 view 1 năm trước Add 13:44 20 Amazing Construction Tools for Smarter Building Projects Top Tech Tools 16,975 view 1 năm trước Add 45:10 The Law of Agency, with University of Virginia School of Law Vice Dean George Geis University of Virginia School of Law 133,652 view 13 năm trước Add 16:06 How to build a (next level) cabinet box | Revealed NS Builders 72,383 view 5 năm trước Add 20:39 Warum es einfacher ist, Vermögen aufzubauen, nachdem man 100.000 € erreicht hat FINANZIELLE BEWUSSTHEIT 830 view 11 tháng trước Add 28:21 VELUX Solar-Rollladen Einbau 🔴 SICHERE Montage von INNEN #AUSPROBIERT 116,123 view 3 năm trước Add 8:48 Best Things to Do in Grand Cayman ViewCation 102,024 view 4 năm trước Add 49:43 View From The Top with Luis Von Ahn, Cofounder and CEO of Duolingo Stanford Graduate School of Business 23,679 view 1 năm trước Add 27:26 Monte Jafferau | Atemberaubende Westalpen Offroad Strecke & Reifenpanne in der Verschränkung? beyondroaming 13,983 view 3 năm trước Add 9:47 How to cut a laminate worktop cleanly. Handmade Originals 212,831 view 6 năm trước Add 1:14:20 Getting Into Law School | Interview: Miriam Ingber and Kristi Jobson The Dispatch 2,555 view 1 năm trước Add 40:43 The Killer Elephant of Mandla Wild World 390,700 view 2 năm trước Add 8:23 9 BEST Things to do in Dominica (& Places to VISIT) | Dominica Travel Guide Before You Go 126,985 view 3 năm trước Add 13:19 PUNK Sovereign Citizen MCGOUGH Makes Judge Simpson Send His Bail NUCLEAR! Trial World 1,735,248 view 1 năm trước Add 39:51 TRUYỆN BOY LOVE | T LỪA HẮN LÀ CON GÁI, HẮN LỪA T LÀ TRAI THẲNG | AUDIO ĐAM MỸ FULL | Sóp của cú Sóp Của Cú 8,070 view 11 tháng trước Add 27:05 CORONATION: Ole Miss PLAYOFF Dreams Rest on South Carolina Showdown | Can Rebels START November Run? Locked On Ole Miss 1,958 view 11 tháng trước Add 35:54 German Generals Captured American Supply Depot and Were Shocked To Find Mountains Of Spare Parts Blind Spot 83 view 11 tháng trước Add 24:23 110 GIGANTISCHE MASCHINEN | FLEXIBLE TECHNOLOGIE, die das ERNTEN NAH AM BODEN BEZWINGT Stahl Giganten 2,864 view 11 tháng trước Add 38:47 Can Heating Be This Different? TOP 2 Korean Heating Systems That Shocked Foreigners king process 1,072,563 view 1 năm trước Add